Fitted with a zirconium dioxide sensor and a nondispersive infrared sensor, the MAT1500 is our number one in terms of its range of application, performance and precision. Measurements are completed within no more than approx. ten seconds. As with the MAT1400, highly precise results can be achieved with single measurements of oxygen concentrations thanks to the min/max detection, even if only a small sample volume is available.
Basic functions
- Easy and intuitive to operate via touchscreen – even for untrained personnel
- Drift-free zirconium dioxide sensor (ZrO2) measures in the measurement range range of 0-100Vol.-%
- Low-drift non-dispersive infrared sensor (NDIR) measures in the measurement range range of 0-100Vol.-%
with an accuracy of ±0,5Vol.-% - Short measurement period
- Only a small sample volume required
- Various interfaces for the convenient transfer of measured values (USB, Ethernet, RS-232)
- Any number of measurement methods for monitoring the measurement process by method, batch, product and/or production line, including limit value monitoring
Highlights
Technical data
| Specification | Gas analyser MAT1500 model | ||||
|---|---|---|---|---|---|
| Average measuremnet periode 1) | 10 seconds | ||||
| Minimal headspace volume 2) | 5ml | ||||
| Heating time | 10 minutes | ||||
| Adjustment | Automatic (menu-driven) | ||||
| Scales | Oxygen, carbon dioxide, nitrogen | ||||
| Methods & users | Over 10000 possible | ||||
| Devices basic data | |||||
| Operation |
7.0“ capacitive touchscreen, 800 x 480 pixels Touchscreen, keyboard, mouse, barcode scanner |
||||
| Dimensions (W x H x D) | 200 mm x 150 mm x 350 mm | ||||
| Weight | 4.6 kg | ||||
| Additional features |
Input of product and batch designations, alarm limit management, user management, Measured value stabilization, air pressure display |
||||
| Temperature data | |||||
| Ambient temperature | 10-50° C | ||||
| Humididy measurement gas | <90% RH (non-condensing) | ||||
| Electrical data | |||||
| Operating voltage | 100-250 VAC | ||||
| Power consumption max. | 60 W | ||||
| Rated frequency | 50/60 Hz | ||||
| 1) after heating-up time, 2) after pre-rinse | |||||
| Analysis data oxygen (O2) | |||||
| Measurement range | 0 – 100 Vol.-% | ||||
| Sensor accuracy / 1 | ±0.02 vol.-% abs. (< 1 vol.-%) | ||||
| Sensor accuracy / 2 | ±3 vol.-% rel. (> 1 vol.-%) | ||||
| Resolution | 0.001 Vol.-% | ||||
| O2 sensor data | |||||
| Type | Zirconium dioxide sensor (ZrO2) | ||||
| Drift | Drift-free | ||||
| Cross-sensitivity | Cross-sensitivity to flammable gases | ||||
| Analysis data carbon dioxide (CO2) | |||||
| Measurement range | 0-100 vol.-% | ||||
| Repeatability | ±0,5 Vol.-% | ||||
| Resolution | 0,1 Vol.-% | ||||
| CO2 sensor data | |||||
| Type | Two-channel NDIR sensor | ||||
| Drift | Low drift < 1 %/month | ||||
| Analysis data nitrogen (N2) | |||||
| Arithmetic determination | Residual content of the gas mixture | ||||
Sensor
At the heart of the gas analysers is the sensor technology
Various models with different sensor technology are optionally available for optimum adaptation to the respective application. The respective proven sensor technology should be selected for each specific application and process. The range of sensors available allows optimum adaptation in terms of measurement range and accuracy:
- Electrochemical cell (EC) for O2 measurement
- Zirconium dioxide cell (ZrO2) for O2 measurement
- Non-dispersive infrared sensor (NDIR) for CO2 measurement
The following overview provides an initial overview. We will be happy to discuss which device models are suitable for your specific requirements in a personal consultation.
Please feel free to contact us
| gas analyser | MAT1100 model | MAT1200 model | MAT 1400 model | MAT1500 model |
|---|---|---|---|---|
| Application |
Sporadic O2-sample check |
Combined O2- and CO2-measurement |
High sample throughput High O2-concentration |
High sample throughput High O2-concentration + Combined O2- and CO2-measurement |
| Advantage model version | Cost-effective option, fast operational readiness, low drift | Cost-effective option, low drift, environmentally compensated CO2 measurement | Long lifespan, fast measurement, high precision measuring lowest O2-concentrations, wide measurement range, drift-free | Long lifespan, fast measurement, high precision measuring lowest O2-concentrations, wide measurement range, ZrO2: drift-free, NDIR: drift-free, environmentally compensated CO2 measurement |
| O2 sensor technology | Electrochemical oxygen cell (EC) | Electrochemical oxygen cell (EC) | Zirconium dioxide sensor (ZrO2) | Zirconium dioxide sensor (ZrO2) |
| CO2 sensor technology | Non-dispersive infrared sensor (NIR) | Non-dispersive infrared sensor (NIR) | Non-dispersive infrared sensor (NIR) | Non-dispersive infrared sensor (NIR) |
| N2 sensor technology | Arithmetic determination | Arithmetic determination | Arithmetic determination | Arithmetic determination |
Documents
| Title | Download |
|---|---|
| Brochure gas analysers | DownloadPreview |
| Overview Gas Mixtures by Industry | DownloadPreview |
| Application gas analysator | DownloadPreview |
You need to login to be able to upload file!
Consumables
-
Stainless steel needles
34,00 €Needle, consisting of: Stainless steel (0.9mm x 38mm), 12 pieces
-
Suction filter
46,00 €Dust and dirt filter to draw in clean air, material PTFE
-
Septa
127,00 €Septa in cardboard dispenser white, self-adhesive
Accessories
-
Transparent protective cover
39,00 €Protective cover for KRÜSS devices: DR6000, DS7000, MAT1000 series and M5000
-
Printer CBM910
304,00 €Matrix printer suitable for many KRÜSS laboratory devices, e.g: DR6000 series, M5000, M3000, P8000 series, FP8000 series
-
Interface cable for printer (CBM910)
23,00 €Interface cable for connecting CBM910 to KRÜSS devices, such as: DR6000 series, P8000 series, FP8000 series
-
Paper roll for printer (CBM910)
3,00 €Replacement printer paper for the CBM910 printer
-
Ink ribbon for printer (CBM910)
12,00 €Ink ribbon as replacement for CBM910 printer, for printing measurement results