Polarimeter P3000 for standard measurements

8.289,00 

Economical polarimeter with a measurement accuracy of ±0.01°

Description

The P3000 polarimeter is the economical solution for standard measurements where a measurement accuracy of ±0.01° is sufficient. Measurements are carried out in a record time of less than 2 seconds. The measured values are displayed either as an optical angle of rotation or in the ICUMSA international sugar scale. There is an option to print results on a serial ASCII printer. The reliable temperature compensation makes it possible to measure at any temperature and obtain the value converted to 20 °C.

Basic functions

  • Very simple Operation via 3.5″ touchscreen
  • Easy-to-understand, menu-guided adjustment
  • Measured values are optionally displayed as optical angle of rotation or in the international sugar scale
  • Reliable temperature compensation (ICUMSA pre-installed)
  • Suitable measurement tubes for every type of sample
  • Measurement up to an optical density of 3.0
  • Particularly short measurement period of 1-2 seconds
  • Conformity with Pharmacopoeias [USP, BP, JP, Ph. Eur. (with temperature control)], GLP, ASTM, ICUMSA, NIST

Technical data

TABLE

Specification Polarimeter P3000 model
Scales Optical rotation (°)
Int. Sugar scale (°Z)
Measurement range ±90°
±259 °Z
Measurement accuracy 2) ±0,01°
±0,01 °Z
Measurement period 2) | 3) 1-2 seconds
Resolution 0,01°
0,01 °Z
Methods & users Not available
Adjustment Automatic (menu-driven)
Parts in contact with the sample Borosilicate glass, PTFE, stainless steel (1.4305)
Sample permeability > 0.1 % (OD3)
Wavelength 589 nm
Max. tube length 220 mm
Additional features Temperature compensation
Temperature data
Temperature control range 1) Retrofittable
Accuracy of temperature control 1) Retrofittable
Temperature measurement accuracy ±0,1 °C
Temperature measurement resolution 0,1 °C
Temperature control Retrofittable
Devices basic data
Operation 3.5″ capacitive touchscreen, 320 x 240 pixel touchscreen, keypad
Interfaces 1x RS-232
Dimensions (W x H x D) 645 mm x 200 mm x 360 mm
Weight 28 kg
Electrical data
Operating voltage 110-250 VAC
Rated frequency 50/60 Hz
Power consumption
(measurement mode)
30 W
Power consumption
(Max.)
40 W

¹) Requires circulation thermostat PT31/PT80, sample chamber bushing P8020 and temperature-controlled measurement tube

²) Under normal conditions for optical rotation measurement (20 °C, 1013 hPa, 50 % relative humidity)

³) After temperature equalization and at OD < 1

Documents

Title Download
Brochure Polarimeter DownloadPreview
Overview polarimeter application areas DownloadPreview
Polarimeter overview Kruess-measurement tubes DownloadPreview
Overview polarimeter standards DownloadPreview
Overview polarimeter samples DownloadPreview


Calibration standards

Consumables

Accessories

Weight 31 kg

Withdraw from contract

Scroll to Top