In conjunction with temperature-controlled measurement tubes and a circulation thermostat, the polarimeter models P8000-T and P8100-T enable a sample temperature control between 8 °C and 35 °C. This makes them suitable for high-precision measurements in quality assurance. These models are the right choice if, for example, a large number of different temperature-controlled measurement tubes are to be used. They are used in purity control, in the determination of chemical composition, in routine analysis with high sample volumes or in the analysis of flavors and fragrances.
Basic functions
- Temperature measurement directly inside the sample
- Accurate, homogeneous water sample temperature control
- Swift coupling system for an easy measurement tube change
- Highest accuracy over the entire measurement range
- Measurement up to an optical density of 3.0
- Chemical-resistant materials
- Intuitive Operation via touch-screen display
- Pre-installed scales, e.g. optical rotation, specific rotation, International sugar scale and
concentration; additional scales can be set up easily - Optional inclusion of peristaltic pump and autosampler
- Compliance with GMP/GLP, 21 CFR Part 11, pharmacopoeias (USP, BP, JP, Ph. Eur.), FDA,
ISO, HACCP, OIML, ASTM, ICUMSA, NIST
Highlights
Technical data
| Specification | P8000-T model | P8100-T model | ||
|---|---|---|---|---|
| Scales |
Optical rotation (°), specific rotation Int. Sugar scale (°Z), concentration (g/100 ml) User-defined (unlimited) |
|||
| Measurement range |
±90° ±259 °Z |
|||
| Measurement accuracy 1) |
±0,003° ±0,01 °Z |
±0,002° ±0,01 °Z |
||
| Measurement period 1) | 2) | 1-2 seconds | |||
| Resolution |
0,001° 0,01 °Z |
|||
| Methods & users | Over 10000 possible | |||
| Adjustment | Automatic (menu-driven) | |||
| Parts in contact with the sample | Borosilicate glass, PTFE, stainless steel (1.4305) | |||
| Sample permeability | > 0.1 % (OD3) | |||
| Wavelength | 589 nm | |||
| Max. tube length | 220 mm | |||
| Additional features | Audit trail; user management; measured value stabilization; temperature compensation | |||
| Temperature data | ||||
| Temperature control range 1) |
PT31= 8-35 °C PT80= 5-80°C |
|||
| Accuracy of temperature control 1) |
PT31= ±0.2 °C PT80= ±0.1 °C |
|||
| Temperature measurement accuracy | ±0,1 °C | |||
| Temperature measurement resolution | 0,1 °C | |||
| Temperature control | With PT31 or PT80 circulation thermostat | |||
| Devices basic data | ||||
| Operation | 7.0″ capacitive touchscreen, 800 x 480 pixel touchscreen, keyboard, mouse, barcode scanner | |||
| Interfaces | 1x USB, 1x RS-232, 1x ethernet, LIMS | |||
| Dimensions (W x H x D) | 670 mm x 200 mm x 360 mm | |||
| Weight | 29 kg | |||
| Electrical data | ||||
| Operating voltage | 110-250 VAC | |||
| Rated frequency | 50/60 Hz | |||
|
Power consumption (measurement mode) |
35 W | |||
|
Power consumption (Max.) |
50 W | |||
¹) Under normal conditions for optical rotation measurement (20 °C, 1013 hPa, 50 % relative humidity)
²) After temperature equalization and at OD < 1
Documents
You need to login to be able to upload file!
Calibration standards
-
Premium quartz control plate PQP-17
2.912,00 €-17° Calibration standard for polarimetry: Accuracy: ±0.001°, with factory certificate, PTB-certifiable
-
Premium quartz control plate PQP+17
2.912,00 €+17° Calibration standard for polarimetry. Accuracy: ±0.001°, with factory certificate, PTB-certifiable
-
Premium quartz control plate PQP+34
2.912,00 €+34° Calibration standard for polarimetry. Accuracy: ±0.001°, with factory certificate, PTB-certifiable
Consumables
-
Out of stock
2 Glass cover plates for polarimeter tubes
37,00 €2 glass cover plates for closing polarimeter tubes, for P8000-T, P3000, P1000-LED
-
2 Rubber rings for cover plates
2,00 €For pressure distribution when tightening polarimeter tubes
Accessories
-
Out of stock
Glass polarimeter tube PRG-100-E
229,00 €Polarimeter tube with filling funnel, length: 100 mm, filling volume 6 ml. For polarimeters P8000/8100-T, P3000
-
Glass polarimeter tube PRG-100-ET
1.516,00 €Polarimeter tube with Stainless steel jacket & filling funnel, length 100 mm. Filling volume 4 ml. For polarimeter P8000/8100-T
-
Out of stock
Glass polarimeter tube PRG-200-E
239,00 €Polarimeter tube with filling funnel, length: 200 mm, filling volume 12 ml. For polarimeters P8000/8100-T, P3000
-
Glass polarimeter tube PRG-200-ET
1.569,00 €Polarimeter tube with Stainless steel jacket & filling funnel, length 200 mm. Filling volume 8 ml. For polarimeter P8000/8100-T
-
Stainless steel temperature sensor
290,00 €Temperature sensor for measuring the sample temperature. For connection to polarimeters, suitable for polarimeters: P8000/8100-T/P3000
-
Stainless steel temperature sensor with PTFE coating
338,00 €temperature sensor for measuring the sample temperature. For connection to polarimeters, suitable for polarimeters: P8000/8100-T and P3000
-
Peristaltic pump
1.062,00 €Peristaltic pump for density meters, DR6000-TF and P8000-TF models
-
Printer CBM910
304,00 €Matrix printer suitable for many KRÜSS laboratory devices, e.g: DR6000 series, M5000, M3000, P8000 series, FP8000 series
-
Interface cable for printer (CBM910)
23,00 €Interface cable for connecting CBM910 to KRÜSS devices, such as: DR6000 series, P8000 series, FP8000 series
-
Paper roll for printer (CBM910)
3,00 €Replacement printer paper for the CBM910 printer
-
Ink ribbon for printer (CBM910)
12,00 €Ink ribbon as replacement for CBM910 printer, for printing measurement results